最新网络赌博官网

Article details

What should I do if the inverter is encrypted?

Date: 2020-01-07 00:49
Browse number : 385
Abstract: Siemens Brand 6SE70 Book Type Inverter: When the setting password cannot be opened, change the data in P358 and P359 to the same. ABB brand ACS600 inverter: Enter the password "23032" in the 16.03 parameter, set the 102.01 parameter to false, and enter all the parameters of the main control board. Mitsubishi brand 740 series inverter: When the setting password cannot be opened, just unplug the panel and then plug it in. Emerson brand TD3000: When the password cannot be set, enter the password 8888. Yaskawa brand Yaskawa G5 inverter: The password is displayed in A1-04. Adjust to this parameter, and then press and hold the MENU button and the RESET button for 10 seconds at the same time, you can see the password. Again to ...

Siemens brand

6SE70 Book-type Inverter: When the setting password cannot be opened, change the data in P358 and P359 to the same.

ABB brand

ACS600 inverter: Enter the password "23032" in the 16.03 parameter, set the 102.01 parameter to false, and enter all the parameters of the main control board.

Mitsubishi brand

740 series inverter: When the setting password cannot be opened, just remove the panel and then plug it in.

Emerson brand

TD3000: When the set password cannot be opened, enter the password 8888.

Yaskawa brand

Yaskawa G5 inverter: The password is displayed in A1-04. Adjust this parameter, and then press and hold the MENU button and the RESET button for 10 seconds at the same time, you can see the password. Then transfer to A1-05 and enter the password to modify the parameters.

Yaskawa G7 inverter: When A1-04 is displayed, press RESET while pressing MENU to display the password setting of A1-05, and then enter this password into A1-04.

Continental brand

590 frequency converter: The universal password is 131122.

Schneider Brand

Set the password, find COD in the SUP menu, and enter 6969.

Fuji brand

VG5 inverter: The password is * the last parameter is No. 200, which is set to 0 and cannot be changed, and set to 1 to be changed.

VG7 inverter: General password FFFF, that is, you must enter FFFF before power on.

Hitachi brand

J300 Inverter: Rename a multi-function terminal to “Initialize” function (parameters C0-C7), then short this terminal to the common terminal “CM1” (or P24), and then turn off the inverter to send power can. If you want to change the terminal "7" to "initialize" function, set the C6 parameter to "7".

Panasonic brand

Panasonic VFO Inverter: Press MODE three times

Press ▲ until 999 is displayed, press ▲ and  at the same time, and then press SET to reset the password.

LS brand

LG-iS5 Inverter: You can see MAK parameters when FU2-94 is set to 240.

Delta brand

B series inverter: The super password is 57522.

H series inverter: The super password is 33582.

S1 series inverter: The super password is 575222.

A series inverter: Press MODE and RESET key together to display P256, press ENTER key to modify this parameter, change 00 to 01, press ENTER to exit to modify all parameters.

INVT brand

CHV, CHE, CHF series inverters: The super password is 50112.

Sanken brand

After the password is set, the parameter CD900 can be set to 36521.

Huichuan brand

The super password is 18181.

Dongyuan brand

M3 series inverter: Change parameter P00 to 05 to see 65 parameters, change P00 to 08 for 2-wire initialization, and change P00 to 03.

Ourui (formerly known as Huifeng) brand

The super password is: 1888.

Puchuan Brand

PI2000 inverter: (1) Set C01 to 222 to enter P14; (2) Set P14 to 3 to refresh the CPU. At this time, PI2000 is set to C01 to 222 to enter P14 parameter settings, P14 is set to 2, P01 is The setting models are G, F, P02 sets the inverter voltage 380V, P03 sets the inverter rated current, P04 sets the voltage display, and P05 sets the current display.

Xilin brand

The super password is 6860.

Jiaxin brand

TX-4T040C inverter: F00 is the user password setting. The factory setting is 8888. If the password of this machine has been modified, the method of unlocking the password is: power on the inverter, short the JP4 solder joint, and the factory password is restored. JP4 is an empty terminal above the motherboard CPU. There are no connectors, but only two pads. Short-circuit it, and then enter the parameter setting. After confirming the 8888 factory password, you can modify the parameters after F00.

Beijing Public Network Security No. 11010802025865